<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-04 03-54-21
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.70 MHz 5/5, 48 dBuV R-PCE
Pilot RDS Phase Difference
6.0 kHz 2.8 kHz -88 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
9 kHz 39 kHz 18907 0,1481
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,7 dBr -1,00 dBr -0,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PCE " 280C 9 (Varied) 1 0 1 5 3:54, 4.07.2025
RT
"Cesky rozhlas Pardubice - zijeme tu s vami "
AF EON
88.9, 93.7, 98.6, 101.0, 102.4, 103.3, 104.7 MHz -
FM Scope Max at: 39 kHz MIN: 9 kHz % above 77 kHz: 0,1481 Acquired: 2025/07/04 3:54:18 Total samples: 18907 Equivalent time: 0:15:45 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: -0,6 dBr MIN: -1,7 dBr AVE: -1,00 dBr % above 0,2 dBr: 0,0 Last value: -0,6 dBr (2025/07/04 3:54:17) 03:40 03:42 03:44 03:46 03:48 03:50 03:52 03:54 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality